                      Fluke 1621 Earth Ground Tester
Catalog: 2840276 | UPC: 095969401210 | Model: Fluke 1621
Fluke 1621 Earth Ground Tester
Compare
Fluke 1621 GEO Earth Ground Tester with 3-Pole Fall-of-Potential and 2-Pole Resistivity
- 3-pole Fall-of-Potential earth testing for basic measurements
- 2-pole resistance measurements for added versatility
- Automatic noise voltage detection for accurate results
- Hazardous voltage warning for increased user protection
- Large backlit LCD display for clear data reading
- Adjustable limit settings with instant alerts when exceeded
- Rugged holster for tough environments
- Compact and portable design
- 600 V CAT II safety rating
Description
The Fluke 1621 Earth Ground Tester is an easy-to-use grounding tool designed for reliable earth resistance testing. It supports both 3-pole Fall-of-Potential and 2-pole ground resistance tests, making it a versatile first-line defense for detecting ground connections. With single-button operation, a rugged holster, and a large backlit display, it is ideal for field service electricians, contractors, utilities, and earth ground specialists.
Applications: Electrical contractors, utility test engineers, substation maintenance, industrial electricians, and lightning protection specialists.
Manufacturer Specifications
| General Specifications | |
|---|---|
| Measuring Functions | 3-pole earth ground resistance, 2-pole AC resistance of a conductor, Interference voltage | 
| Intrinsic Error | Guaranteed for one year within reference temperature range | 
| Measuring Rate | 2 measurements/second | 
| Battery | One 9 V alkaline (LR61) | 
| Battery Indicator | LO-BAT displayed if voltage drops below 6.5 V | 
| Voltages | Between H/C2 and E/C1: 250 Veff max; Between S/P2 and E/C1: 250 Veff max | 
| Standard Infrared Lens Type | Field of view: 17° × 17°, IFOV 2.50 mRad, Minimum focus: 15 cm (6 in) | 
| Climatic Class | VDE/VDI 3540 RZ (DIN 40040, 4/87) | 
| Temperature Performance | Working: -10 °C to +50 °C; Operating: 0 °C to +35 °C; Storage: -20 °C to +60 °C; Reference: +23 °C ± 2 °C | 
| Temperature Coefficient | ± 0.1 % of range per K | 
| Safety | IEC/EN 61010-1, 600 V CAT II, Pollution Degree 2 | 
| Dimensions | 113 × 54 × 216 mm (4.5 × 2.1 × 8.5 in) including holster | 
| Weight | 850 g (1.9 lbs) including standard accessories | 
| Electrical Specifications | |
| Max Deviations | E1 Position: 0% | E2 Supply Voltage: 0% | E3 Temperature: 2.3% | E4 Interference Voltage (20 V): 0.6% | E5 Probe Resistance: 10% | 
| Test Voltage | 3.7 kV | 
| Protection | IP40 (IEC/EN 60529) | 
| Electromagnetic Compatibility | IEC/EN 61326 Class B (Emission), IEC/EN 61326 Annex C (Immunity) | 
| RE Resistance Measurement | |
| Method | Current-voltage measurement with improved cross-talk attenuation, per IEC/EN 61557-5 | 
| Open Circuit Voltage | 23–24 V AC | 
| Short Circuit Current | > 50 mA AC | 
| Measuring Frequency | 128 Hz | 
| Max Overload | 250 Veff | 
| Measuring Time | 8 seconds (average after START) | 
| Limit Input | Retains set value even if power is off (with sufficient battery) | 
| Resolution Changeover | RH < 7 kΩ → 0.01 Ω; RH < 50 kΩ → 0.1 Ω; RH > 50 kΩ → 1 Ω | 
| Interference Voltage Display | Vmax 30 Veff | 
| Common Mode Rejection | > 80 dB at 50/60 Hz | 
| Ri | 680 kΩ | 
| Measuring Uncertainty | < 10 % for pure AC/DC signals | 
| Measuring Range | |
| 0.15 Ω to 20 Ω | Resolution: 0.01 Ω | Display: 0–19.99 Ω | 
| 200 Ω | Resolution: 0.1 Ω | Display: 20–199.9 Ω | 
| 2 kΩ | Resolution: 1 Ω | Display: 200–1999 Ω | 
| Intrinsic Uncertainty | ± (6% of measured value + 5D) | 
| Operating Uncertainty | ± (18% of measured value + 5D) per IEC 61557 | 
Tech Specs
| Ground Testers Template | |
|---|---|
| Type | 3-Pole | 
| Display | Digital | 
| Ground Resistance Range | 2 kΩ | 
| Accuracy | ± (6% + 5D intrinsic), ± (18% + 5D operating) | 
| Measuring Current | 50 mA | 
| Measuring Voltage | 24 V | 
| Measuring Frequency | 128 Hz | 
| Soil Resistivity | No | 
| Stakeless Capability | No | 
| Power Supply | 9 V Battery | 
| CAT Rating | CAT II | 
| CAT Voltage | 600 V | 
| Auto Ranging | Yes | 
Test Equipment General Attributes
| Unique Features | 3-pole and 2-pole methods, auto noise voltage detection, adjustable limit alerts, single-button operation, portable design | 
|---|---|
| Warranty | 2 Years | 
| IP Rating | IP40 | 
| Product Weight | 1.9 lbs | 
| Product Height | 8.5 in | 
| Product Length | 4.5 in | 
| Product Width | 2.1 in | 
| Shipping Weight | 6 lbs | 
| Shipping Dimensions | 9.4 × 7.6 × 2.8 in | 
| Data Logging | No | 
| Battery Type | 9 V | 
| Power Supply | Battery Powered | 
| Country of Origin | Romania | 
| UPC | 095969401210 | 
Fluke 1621 Earth Ground Tester
Catalog: 2840276 | UPC: 095969401210 | Model: Fluke 1621
Fluke 1621 Earth Ground Tester
Compare
Fluke 1621 GEO Earth Ground Tester with 3-Pole Fall-of-Potential and 2-Pole Resistivity
- 3-pole Fall-of-Potential earth testing for basic measurements
- 2-pole resistance measurements for added versatility
- Automatic noise voltage detection for accurate results
- Hazardous voltage warning for increased user protection
- Large backlit LCD display for clear data reading
- Adjustable limit settings with instant alerts when exceeded
- Rugged holster for tough environments
- Compact and portable design
- 600 V CAT II safety rating
Description
The Fluke 1621 Earth Ground Tester is an easy-to-use grounding tool designed for reliable earth resistance testing. It supports both 3-pole Fall-of-Potential and 2-pole ground resistance tests, making it a versatile first-line defense for detecting ground connections. With single-button operation, a rugged holster, and a large backlit display, it is ideal for field service electricians, contractors, utilities, and earth ground specialists.
Applications: Electrical contractors, utility test engineers, substation maintenance, industrial electricians, and lightning protection specialists.
Manufacturer Specifications
| General Specifications | |
|---|---|
| Measuring Functions | 3-pole earth ground resistance, 2-pole AC resistance of a conductor, Interference voltage | 
| Intrinsic Error | Guaranteed for one year within reference temperature range | 
| Measuring Rate | 2 measurements/second | 
| Battery | One 9 V alkaline (LR61) | 
| Battery Indicator | LO-BAT displayed if voltage drops below 6.5 V | 
| Voltages | Between H/C2 and E/C1: 250 Veff max; Between S/P2 and E/C1: 250 Veff max | 
| Standard Infrared Lens Type | Field of view: 17° × 17°, IFOV 2.50 mRad, Minimum focus: 15 cm (6 in) | 
| Climatic Class | VDE/VDI 3540 RZ (DIN 40040, 4/87) | 
| Temperature Performance | Working: -10 °C to +50 °C; Operating: 0 °C to +35 °C; Storage: -20 °C to +60 °C; Reference: +23 °C ± 2 °C | 
| Temperature Coefficient | ± 0.1 % of range per K | 
| Safety | IEC/EN 61010-1, 600 V CAT II, Pollution Degree 2 | 
| Dimensions | 113 × 54 × 216 mm (4.5 × 2.1 × 8.5 in) including holster | 
| Weight | 850 g (1.9 lbs) including standard accessories | 
| Electrical Specifications | |
| Max Deviations | E1 Position: 0% | E2 Supply Voltage: 0% | E3 Temperature: 2.3% | E4 Interference Voltage (20 V): 0.6% | E5 Probe Resistance: 10% | 
| Test Voltage | 3.7 kV | 
| Protection | IP40 (IEC/EN 60529) | 
| Electromagnetic Compatibility | IEC/EN 61326 Class B (Emission), IEC/EN 61326 Annex C (Immunity) | 
| RE Resistance Measurement | |
| Method | Current-voltage measurement with improved cross-talk attenuation, per IEC/EN 61557-5 | 
| Open Circuit Voltage | 23–24 V AC | 
| Short Circuit Current | > 50 mA AC | 
| Measuring Frequency | 128 Hz | 
| Max Overload | 250 Veff | 
| Measuring Time | 8 seconds (average after START) | 
| Limit Input | Retains set value even if power is off (with sufficient battery) | 
| Resolution Changeover | RH < 7 kΩ → 0.01 Ω; RH < 50 kΩ → 0.1 Ω; RH > 50 kΩ → 1 Ω | 
| Interference Voltage Display | Vmax 30 Veff | 
| Common Mode Rejection | > 80 dB at 50/60 Hz | 
| Ri | 680 kΩ | 
| Measuring Uncertainty | < 10 % for pure AC/DC signals | 
| Measuring Range | |
| 0.15 Ω to 20 Ω | Resolution: 0.01 Ω | Display: 0–19.99 Ω | 
| 200 Ω | Resolution: 0.1 Ω | Display: 20–199.9 Ω | 
| 2 kΩ | Resolution: 1 Ω | Display: 200–1999 Ω | 
| Intrinsic Uncertainty | ± (6% of measured value + 5D) | 
| Operating Uncertainty | ± (18% of measured value + 5D) per IEC 61557 | 
Tech Specs
| Ground Testers Template | |
|---|---|
| Type | 3-Pole | 
| Display | Digital | 
| Ground Resistance Range | 2 kΩ | 
| Accuracy | ± (6% + 5D intrinsic), ± (18% + 5D operating) | 
| Measuring Current | 50 mA | 
| Measuring Voltage | 24 V | 
| Measuring Frequency | 128 Hz | 
| Soil Resistivity | No | 
| Stakeless Capability | No | 
| Power Supply | 9 V Battery | 
| CAT Rating | CAT II | 
| CAT Voltage | 600 V | 
| Auto Ranging | Yes | 
Test Equipment General Attributes
| Unique Features | 3-pole and 2-pole methods, auto noise voltage detection, adjustable limit alerts, single-button operation, portable design | 
|---|---|
| Warranty | 2 Years | 
| IP Rating | IP40 | 
| Product Weight | 1.9 lbs | 
| Product Height | 8.5 in | 
| Product Length | 4.5 in | 
| Product Width | 2.1 in | 
| Shipping Weight | 6 lbs | 
| Shipping Dimensions | 9.4 × 7.6 × 2.8 in | 
| Data Logging | No | 
| Battery Type | 9 V | 
| Power Supply | Battery Powered | 
| Country of Origin | Romania | 
| UPC | 095969401210 | 
Fluke 1621 Earth Ground Tester
- Regular price
- $0.00
- Sale price
- $0.00
- Regular price
- 
				
Couldn't load pickup availability
Popup Title
Popup Title
 
 
 
					Check Out These Related Products
We provide a diverse choice of reliable safety solutions from top manufacturers such as 3M, Avon Protection, BW Technologies, MSA Safety, and Philips, which are recognized for their performance and dependability. Every product, from protective clothing to sophisticated detection systems, Guardian Safety Supply provides original, high-quality equipment that satisfies your safety requirements.