                      Fluke 355 True-RMS 2000 A Clamp Meter (350 Series)
Rating: 5 (1 Review) | Catalog: 2840265 | UPC: 095969401203 | Model: Fluke 355
Fluke 355 AC/DC TRMS Clamp Meter, 2000A
Compare
Fluke 355 True-RMS AC/DC Clamp Meter, 2000A AC/DC
- Large 58 mm (2.3 in) jaw capacity suitable for large or multiple conductors
- Handles up to 2000 A AC+DC true-RMS, 1400 A AC, and 2000 A DC
- In-rush current measurement captures power-on surge with accuracy
- CAT IV 600 V, CAT III 1000 V safety rating
- Resistance to 400KΩ with continuity beeper (355 only)
- High voltage measurement up to 1000 V AC+DC (355 only)
- MIN, MAX, AVG functions for quick analysis
- Frequency measurement up to 1 kHz
- Display hold to capture readings
- Large backlit display for visibility in low light
- Low-pass filter to stabilize noisy load readings
Description
Fluke 355 True-RMS Clamp Meter
The Fluke 355 and 353 clamp meters are versatile and rugged tools designed for high-current applications up to 2000 A. With extra-wide jaws for large conductors, these clamp meters provide reliable and safe measurements. The Fluke 355 adds voltage and resistance capabilities, making it a multifunctional tool for electrical contractors, industrial service technicians, and utility applications.
Manufacturer Specs
Electrical Specifications
| Current measurement dc and ac 10 Hz to 100 Hz | |
|---|---|
| Range | 40 A | 
| Resolution | 10 mA | 
| Accuracy, A | 1.5 % rdg + 15 digits | 
| Trigger Level for Inrush | 0.50 A | 
| Trigger Level for Hz Filter OFF | 2.50 A | 
| Trigger Level for Hz Filter ON | 0.50 A | 
| Range | 400 A | 
| Resolution | 100 mA | 
| Accuracy, A | 1.5 % rdg + 5 digits | 
| Trigger Level for Inrush | 5.0 A | 
| Trigger Level for Hz Filter OFF | 2.5 A | 
| Trigger Level for Hz Filter ON | 2.5 A | 
| Range | 2000 A; 1400 ac rms | 
| Resolution | 1 A | 
| Accuracy, A | 1.5 % rdg + 5 digits | 
| Trigger Level for Inrush | 5 A | 
| Trigger Level for Hz Filter OFF | 8 A | 
| Trigger Level for Hz Filter ON | 8 A | 
| Crest Factor (50/60 Hz) | |
| 40 A Range | 2 @ 33 A, 2.4 @ 27 A | 
| 400 A Range | 2 @ 330 A, 2.4 @ 270 A | 
| 2000 A Range | 2 @ 1000 A, 2.4 @ 833 A | 
| Current measurement ac 100.1 Hz to 1 kHz | |
|---|---|
| Range | 40 A | 
| Resolution | 10 mA | 
| Accuracy > 10 A | 3.5 % rdg + 15 digits | 
| Trigger Levels | 0.50 A / 2.50 A | 
| Range | 400 A | 
| Resolution | 100 mA | 
| Accuracy > 10 A | 3.5 % rdg + 5 digits | 
| Trigger Levels | 5.0 A / 2.5 A | 
| Range | 2000 A; 1400 ac rms | 
| Resolution | 1 A | 
| Accuracy > 10 A | 3.5 % rdg + 5 digits | 
| Trigger Levels | 5 A / 8 A | 
| Voltage measurement (355 only, dc/ac 10 Hz–100 Hz) | |
|---|---|
| Range | 4 V / 40 V / 400 V / 600 V ac rms / 1000 V dc | 
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | 
| Accuracy | 1 % rdg + 5–10 digits (range dependent) | 
| Trigger Levels | 0.05 V to 6 V (range dependent) | 
| Voltage measurement (355 only, ac 100.1 Hz–1 kHz) | |
|---|---|
| Range | 4 V / 40 V / 400 V / 600 V ac rms | 
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | 
| Accuracy | 3 % rdg + 5–10 digits | 
| Trigger Levels | 0.05 V to 6 V | 
| Ohms measurement (355 only) | |
|---|---|
| Ranges | 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ | 
| Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω | 
| Accuracy | 1.5 % + 5 digits | 
| Continuity Beeper | On ≤ 30 Ω, Off ≥ 100 Ω | 
| Frequency Measurement | |
|---|---|
| Measurement Range | 5.0 Hz to 1 kHz | 
| Resolution | 0.1 Hz (15–399.9 Hz); 1 Hz (400 Hz–1 kHz) | 
| Accuracy | 0.2 % + 2 counts (5–100 Hz), 0.5 % + 5 counts (100.1 Hz–1 kHz) | 
| Trigger Level | Refer to current and voltage tables | 
| Note | Add 2 % to error spec for CF > 2 | 
General Specifications
| Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 | 
| Battery Life | 100 hours (typical usage, backlight off) | 
| Test Leads | Rated to 1000 V | 
| Weight | 0.814 kg (1.8 lb) | 
| Jaw Size | 58 mm (2.28 in) | 
| Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) | 
| Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | 
Environmental Specifications
| Operating Temperature | 0 °C to +50 °C (32 °F to 122 °F) | 
| Storage Temperature | -20 °C to +60 °C (-4 °F to 140 °F) | 
| Operating Humidity | 0 to 95 % (non-condensing) | 
| Operating Altitude | 2000 m | 
| Storage Altitude | 10,000 m | 
| IP Rating | IP42 (indoor use only) | 
| Drop Test | 1 m | 
| EMI/RFI/EMC | FCC part 15, IEC/EN 61326-1 class B, IEC/EN 61326 3V/m | 
| Temperature Coefficients | Current: 0.1 % of reading/°C outside 22–24 °C Voltage: 0.1 % of reading/°C outside 22–24 °C | 
Tech Specs
Clamp Meters/Clamp Meters Template
| True RMS | Yes | 
| Maximum Current AC | 1400 A | 
| Maximum Current DC | 2000 A | 
| Maximum Voltage AC | 1000 V | 
| Maximum Voltage DC | 1000 V | 
| Maximum Conductor Size | 2.18 IN | 
| Resistance | Yes | 
| Capacitance | No | 
| Auto Ranging/Manual | Auto Ranging | 
| In-Rush Current | Yes | 
Test Equipment General Attributes
| Unique Features | 58 mm jaw for large/multiple conductors; In-rush capture; Large backlit display; CAT IV 600 V / CAT III 1000 V | 
| Warranty | 3 YEARS | 
| Safety Approval | CE, CSA | 
| IP Rating | IP42 | 
| Product Weight | 1.8 LBS | 
| Product Height | 2 IN | 
| Product Length | 12 IN | 
| Product Width | 3.75 IN | 
| Data Logging | No | 
| HTS/Schedule B Number | 9030.31.0000 | 
| ECCN Number | EAR99 | 
| Calibration Included | None | 
| Power Supply Voltage | Battery Powered | 
| Country of Origin | China | 
| Shipping Height | 4.25 IN | 
| Shipping Length | 14.00 IN | 
| Shipping Width | 8.50 IN | 
| CA Residents | Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov | 
Fluke 355 True-RMS 2000 A Clamp Meter (350 Series)
Rating: 5 (1 Review) | Catalog: 2840265 | UPC: 095969401203 | Model: Fluke 355
Fluke 355 AC/DC TRMS Clamp Meter, 2000A
Compare
Fluke 355 True-RMS AC/DC Clamp Meter, 2000A AC/DC
- Large 58 mm (2.3 in) jaw capacity suitable for large or multiple conductors
- Handles up to 2000 A AC+DC true-RMS, 1400 A AC, and 2000 A DC
- In-rush current measurement captures power-on surge with accuracy
- CAT IV 600 V, CAT III 1000 V safety rating
- Resistance to 400KΩ with continuity beeper (355 only)
- High voltage measurement up to 1000 V AC+DC (355 only)
- MIN, MAX, AVG functions for quick analysis
- Frequency measurement up to 1 kHz
- Display hold to capture readings
- Large backlit display for visibility in low light
- Low-pass filter to stabilize noisy load readings
Description
Fluke 355 True-RMS Clamp Meter
The Fluke 355 and 353 clamp meters are versatile and rugged tools designed for high-current applications up to 2000 A. With extra-wide jaws for large conductors, these clamp meters provide reliable and safe measurements. The Fluke 355 adds voltage and resistance capabilities, making it a multifunctional tool for electrical contractors, industrial service technicians, and utility applications.
Manufacturer Specs
Electrical Specifications
| Current measurement dc and ac 10 Hz to 100 Hz | |
|---|---|
| Range | 40 A | 
| Resolution | 10 mA | 
| Accuracy, A | 1.5 % rdg + 15 digits | 
| Trigger Level for Inrush | 0.50 A | 
| Trigger Level for Hz Filter OFF | 2.50 A | 
| Trigger Level for Hz Filter ON | 0.50 A | 
| Range | 400 A | 
| Resolution | 100 mA | 
| Accuracy, A | 1.5 % rdg + 5 digits | 
| Trigger Level for Inrush | 5.0 A | 
| Trigger Level for Hz Filter OFF | 2.5 A | 
| Trigger Level for Hz Filter ON | 2.5 A | 
| Range | 2000 A; 1400 ac rms | 
| Resolution | 1 A | 
| Accuracy, A | 1.5 % rdg + 5 digits | 
| Trigger Level for Inrush | 5 A | 
| Trigger Level for Hz Filter OFF | 8 A | 
| Trigger Level for Hz Filter ON | 8 A | 
| Crest Factor (50/60 Hz) | |
| 40 A Range | 2 @ 33 A, 2.4 @ 27 A | 
| 400 A Range | 2 @ 330 A, 2.4 @ 270 A | 
| 2000 A Range | 2 @ 1000 A, 2.4 @ 833 A | 
| Current measurement ac 100.1 Hz to 1 kHz | |
|---|---|
| Range | 40 A | 
| Resolution | 10 mA | 
| Accuracy > 10 A | 3.5 % rdg + 15 digits | 
| Trigger Levels | 0.50 A / 2.50 A | 
| Range | 400 A | 
| Resolution | 100 mA | 
| Accuracy > 10 A | 3.5 % rdg + 5 digits | 
| Trigger Levels | 5.0 A / 2.5 A | 
| Range | 2000 A; 1400 ac rms | 
| Resolution | 1 A | 
| Accuracy > 10 A | 3.5 % rdg + 5 digits | 
| Trigger Levels | 5 A / 8 A | 
| Voltage measurement (355 only, dc/ac 10 Hz–100 Hz) | |
|---|---|
| Range | 4 V / 40 V / 400 V / 600 V ac rms / 1000 V dc | 
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | 
| Accuracy | 1 % rdg + 5–10 digits (range dependent) | 
| Trigger Levels | 0.05 V to 6 V (range dependent) | 
| Voltage measurement (355 only, ac 100.1 Hz–1 kHz) | |
|---|---|
| Range | 4 V / 40 V / 400 V / 600 V ac rms | 
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | 
| Accuracy | 3 % rdg + 5–10 digits | 
| Trigger Levels | 0.05 V to 6 V | 
| Ohms measurement (355 only) | |
|---|---|
| Ranges | 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ | 
| Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω | 
| Accuracy | 1.5 % + 5 digits | 
| Continuity Beeper | On ≤ 30 Ω, Off ≥ 100 Ω | 
| Frequency Measurement | |
|---|---|
| Measurement Range | 5.0 Hz to 1 kHz | 
| Resolution | 0.1 Hz (15–399.9 Hz); 1 Hz (400 Hz–1 kHz) | 
| Accuracy | 0.2 % + 2 counts (5–100 Hz), 0.5 % + 5 counts (100.1 Hz–1 kHz) | 
| Trigger Level | Refer to current and voltage tables | 
| Note | Add 2 % to error spec for CF > 2 | 
General Specifications
| Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 | 
| Battery Life | 100 hours (typical usage, backlight off) | 
| Test Leads | Rated to 1000 V | 
| Weight | 0.814 kg (1.8 lb) | 
| Jaw Size | 58 mm (2.28 in) | 
| Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) | 
| Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | 
Environmental Specifications
| Operating Temperature | 0 °C to +50 °C (32 °F to 122 °F) | 
| Storage Temperature | -20 °C to +60 °C (-4 °F to 140 °F) | 
| Operating Humidity | 0 to 95 % (non-condensing) | 
| Operating Altitude | 2000 m | 
| Storage Altitude | 10,000 m | 
| IP Rating | IP42 (indoor use only) | 
| Drop Test | 1 m | 
| EMI/RFI/EMC | FCC part 15, IEC/EN 61326-1 class B, IEC/EN 61326 3V/m | 
| Temperature Coefficients | Current: 0.1 % of reading/°C outside 22–24 °C Voltage: 0.1 % of reading/°C outside 22–24 °C | 
Tech Specs
Clamp Meters/Clamp Meters Template
| True RMS | Yes | 
| Maximum Current AC | 1400 A | 
| Maximum Current DC | 2000 A | 
| Maximum Voltage AC | 1000 V | 
| Maximum Voltage DC | 1000 V | 
| Maximum Conductor Size | 2.18 IN | 
| Resistance | Yes | 
| Capacitance | No | 
| Auto Ranging/Manual | Auto Ranging | 
| In-Rush Current | Yes | 
Test Equipment General Attributes
| Unique Features | 58 mm jaw for large/multiple conductors; In-rush capture; Large backlit display; CAT IV 600 V / CAT III 1000 V | 
| Warranty | 3 YEARS | 
| Safety Approval | CE, CSA | 
| IP Rating | IP42 | 
| Product Weight | 1.8 LBS | 
| Product Height | 2 IN | 
| Product Length | 12 IN | 
| Product Width | 3.75 IN | 
| Data Logging | No | 
| HTS/Schedule B Number | 9030.31.0000 | 
| ECCN Number | EAR99 | 
| Calibration Included | None | 
| Power Supply Voltage | Battery Powered | 
| Country of Origin | China | 
| Shipping Height | 4.25 IN | 
| Shipping Length | 14.00 IN | 
| Shipping Width | 8.50 IN | 
| CA Residents | Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov | 
Fluke 355 True-RMS 2000 A Clamp Meter (350 Series)
- Regular price
- $0.00
- Sale price
- $0.00
- Regular price
- 
				
Couldn't load pickup availability
Popup Title
Popup Title
 
					Check Out These Related Products
We provide a diverse choice of reliable safety solutions from top manufacturers such as 3M, Avon Protection, BW Technologies, MSA Safety, and Philips, which are recognized for their performance and dependability. Every product, from protective clothing to sophisticated detection systems, Guardian Safety Supply provides original, high-quality equipment that satisfies your safety requirements.