                      Fluke 707 Loop Calibrator
Rating: 4.5 (2 Reviews) | Catalog: 1617262 | UPC: 095969107150 | Model: Fluke 707
Fluke 707
Compare
Fluke 707 Loop Calibrator with Quick Click Knob, .015% Accuracy
- High performance loop calibrator for calibration, repair, and maintenance
- Large display and quick-click interface for one-handed operation
- Simultaneous mA and % readout
- mA accuracy of 0.015%
- 1 µA resolution for mA source, simulate, and measure
Description
Fluke 707 - Loop Calibrator
High performance loop calibrator with quick-click knob for calibration, repair, and maintenance. Features a large display with simultaneous mA and % readout. Accuracy of 0.015% with 1 µA resolution. Rugged, compact, and EMI/dust/splash resistant with removable battery door for easy changes.
Manufacturer Specs
General Specifications
| Maximum Voltage | 30 volts; Non-operating temp –4 °C to 60 °C | 
| Operating Temperature | –10 °C to 55 °C | 
| Relative Humidity | 95 % (10–30 °C); 75 % (30–40 °C); 45 % (40–50 °C); 35 % (50–55 °C) | 
| Operating Altitude | 3,000 m max | 
| Shock | 1 m drop test | 
| Vibration | Random, 2 g, 5 Hz–500 Hz | 
| Safety | CSA C22.2 No. 1010.1:1992 | 
| EMC | EN50082-1:1992, EN55022:1994 Class B | 
| Power | 9 V battery ANSI/NEDA 1604A or IEC 6LR61; two batteries in 718 | 
| Warranty | 3 years | 
Current Measurement
| Range | 0 to 24 mA | 
| Resolution | 0.001 mA | 
| Accuracy | 0.015% Rdg + 2 LSD | 
Current Sourcing
| Range | 0 to 20 mA or 4 to 20 mA | 
| Accuracy | 0.015% Rdg + 2 LSD | 
| Drive Capability | 1200 Ω; 950 Ω at 20 mA in HART mode | 
Current Simulation
| Range | 0 to 20 mA or 4 to 20 mA | 
| Accuracy | 0.015% Rdg + 2 LSD | 
| External Loop Voltage Requirement | 12–30 V | 
Loop Power
| While measuring mA | 24 V | 
Voltage Measurement
| Range | 0 to 28 V DC | 
| Resolution | 1 mV | 
| Accuracy | 0.015% Rdg + 2 LSD | 
Environmental Specifications
| Operating Temperature | -10 °C to 55 °C | 
| Storage Temperature | -30 °C to 60 °C | 
| Humidity | 0–90% (0–35 °C); 0–70% (35–55 °C) | 
| Temperature Coefficient | ±0.005% of range/°C outside 18–28 °C | 
Safety Specifications
| Safety | CSA C22.2 No. 1010.1:1992 | 
| EMC | EN50082-1:1992, EN55022:1994 Class B | 
| Maximum Voltage | 30 V | 
Mechanical & General Specifications
| Size | 152 x 70 x 41 mm | 
| Weight | 224 g (340 g with holster) | 
| Batteries | One 9V Alkaline | 
| Warranty | 3 years | 
| Shock & Vibration | MIL-T-28800 Class 2 | 
| Display current and % of span | Yes | 
| Auto step, auto ramp | Yes | 
| Span Check | Yes | 
Tech Specs
Test Equipment General Attributes
| Product Height | 3.25 IN | 
| Product Length | 10.25 IN | 
| Product Width | 6.00 IN | 
| Data Logging | No | 
| Calibration Included | NIST Calibration | 
| Country of Origin | China | 
Fluke 707 Loop Calibrator
Rating: 4.5 (2 Reviews) | Catalog: 1617262 | UPC: 095969107150 | Model: Fluke 707
Fluke 707
Compare
Fluke 707 Loop Calibrator with Quick Click Knob, .015% Accuracy
- High performance loop calibrator for calibration, repair, and maintenance
- Large display and quick-click interface for one-handed operation
- Simultaneous mA and % readout
- mA accuracy of 0.015%
- 1 µA resolution for mA source, simulate, and measure
Description
Fluke 707 - Loop Calibrator
High performance loop calibrator with quick-click knob for calibration, repair, and maintenance. Features a large display with simultaneous mA and % readout. Accuracy of 0.015% with 1 µA resolution. Rugged, compact, and EMI/dust/splash resistant with removable battery door for easy changes.
Manufacturer Specs
General Specifications
| Maximum Voltage | 30 volts; Non-operating temp –4 °C to 60 °C | 
| Operating Temperature | –10 °C to 55 °C | 
| Relative Humidity | 95 % (10–30 °C); 75 % (30–40 °C); 45 % (40–50 °C); 35 % (50–55 °C) | 
| Operating Altitude | 3,000 m max | 
| Shock | 1 m drop test | 
| Vibration | Random, 2 g, 5 Hz–500 Hz | 
| Safety | CSA C22.2 No. 1010.1:1992 | 
| EMC | EN50082-1:1992, EN55022:1994 Class B | 
| Power | 9 V battery ANSI/NEDA 1604A or IEC 6LR61; two batteries in 718 | 
| Warranty | 3 years | 
Current Measurement
| Range | 0 to 24 mA | 
| Resolution | 0.001 mA | 
| Accuracy | 0.015% Rdg + 2 LSD | 
Current Sourcing
| Range | 0 to 20 mA or 4 to 20 mA | 
| Accuracy | 0.015% Rdg + 2 LSD | 
| Drive Capability | 1200 Ω; 950 Ω at 20 mA in HART mode | 
Current Simulation
| Range | 0 to 20 mA or 4 to 20 mA | 
| Accuracy | 0.015% Rdg + 2 LSD | 
| External Loop Voltage Requirement | 12–30 V | 
Loop Power
| While measuring mA | 24 V | 
Voltage Measurement
| Range | 0 to 28 V DC | 
| Resolution | 1 mV | 
| Accuracy | 0.015% Rdg + 2 LSD | 
Environmental Specifications
| Operating Temperature | -10 °C to 55 °C | 
| Storage Temperature | -30 °C to 60 °C | 
| Humidity | 0–90% (0–35 °C); 0–70% (35–55 °C) | 
| Temperature Coefficient | ±0.005% of range/°C outside 18–28 °C | 
Safety Specifications
| Safety | CSA C22.2 No. 1010.1:1992 | 
| EMC | EN50082-1:1992, EN55022:1994 Class B | 
| Maximum Voltage | 30 V | 
Mechanical & General Specifications
| Size | 152 x 70 x 41 mm | 
| Weight | 224 g (340 g with holster) | 
| Batteries | One 9V Alkaline | 
| Warranty | 3 years | 
| Shock & Vibration | MIL-T-28800 Class 2 | 
| Display current and % of span | Yes | 
| Auto step, auto ramp | Yes | 
| Span Check | Yes | 
Tech Specs
Test Equipment General Attributes
| Product Height | 3.25 IN | 
| Product Length | 10.25 IN | 
| Product Width | 6.00 IN | 
| Data Logging | No | 
| Calibration Included | NIST Calibration | 
| Country of Origin | China | 
Fluke 707 Loop Calibrator
- Regular price
- $0.00
- Sale price
- $0.00
- Regular price
- 
				
Couldn't load pickup availability
Popup Title
Popup Title
 
					Check Out These Related Products
We provide a diverse choice of reliable safety solutions from top manufacturers such as 3M, Avon Protection, BW Technologies, MSA Safety, and Philips, which are recognized for their performance and dependability. Every product, from protective clothing to sophisticated detection systems, Guardian Safety Supply provides original, high-quality equipment that satisfies your safety requirements.