 
                   
                   
                       
                      Fluke 726 Multifunction Precision Process Calibrator
Key Features
- More precise measurement and calibration source performance, accuracies of 0.01%
- Two separate channels; measure, source and view process signals simultaneously
- Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
- Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
- Source mA with simultaneous pressure measurement to conduct valve and I/P tests
- Integrated pressure switch test captures set, reset and deadband of a switch
- Memory storage for up to 8 calibration results
- Transmitter error% calculation to interpret results without a calculator
- Perform fast linearity tests with auto step and auto ramp
- 24 V loop supply with simultaneous mA measurement
- Frequency totalizer and frequency pulse train source mode for flowmeter testing
- HART mode with 250 ohm resistor for HART instrumentation compatibility
- Custom RTD curves for certified RTD probes
- Improved reliability with new voltage input protection
- Three-year warranty
Fluke 726 Accessories
- Alligator Clips
- Banana Type Test Leads
- Calibration Pumps
- Cases
- Current Clamp Adaptors / Current Clamps
- DMM Probe Kits
- DMM Probes with Leads
- Hook Test Leads
- Pincer Test Leads
- Pressure Calibrator Modules
- Probe Bodies
- Telecom Test Leads
- Temperature Probes
Description
FLUKE 726 - Precision Multifunction Process Calibrator
The Fluke 726 is designed for the process industry with broad workload coverage, calibration power, and unsurpassed accuracy. It measures and sources almost all process parameters and can calibrate almost anything. It also interprets results without a calculator and stores measurement data for later analysis.
Features include a split-screen display, thermocouple input/output with automatic compensation, manual and automatic stepping/ramping, calibration screen storage, and remote control capability via PC.
Manufacturer Specifications
| Voltage DC | 30.000 V 0.01%+2 mV (upper) 20.000 V 0.01%+2 mV (lower) 90.00 mV 0.01%+10 µV -10.00 mV to 75.00 mV 0.025%+1 | 
| Current DC | 24.000 mA 0.01%+2 µA | 
| Resistance | 0–4000 Ω: ±0.015% | 
| Frequency | 2–1000 CPM: 0.05%+0.1 cpm 1–1000 Hz: 0.05%+0.1 Hz 1–15 kHz: 0.05%+0.01 kHz Sensitivity: 1 V p-p min | 
| Pressure | Accuracy 0.025% of range using 29 pressure modules (differential, gauge, vacuum, absolute, dual, high pressure) | 
| Source Accuracy (Voltage DC) | 100.00 mV 0.01%+10 µV 20.000 V 0.01%+2 mV -10.00 mV to 75.00 mV 0.025%+1 | 
| Source Accuracy (Current DC) | 24.000 mA (Source) 0.01%+2 µA 24.000 mA (Simulate) 0.01%+2 µA | 
| Source Accuracy (Resistance) | 5–400 Ω: 0.015%+0.1 Ω (0.1–0.5 mA) 5–400 Ω: 0.015%+0.05 Ω (0.5–3 mA) 400–1500 Ω: 0.015%+0.5 Ω (0.05–0.8 mA) 1500–4000 Ω: 0.015%+0.5 Ω (0.05–0.4 mA) | 
| Source Accuracy (Frequency) | 2–1000 CPM: 0.05% 1–1000 Hz: 0.05% 1–10 kHz: 0.25% 10–15 kHz: 0.5% Waveform: 5 V p-p squarewave | 
| RTDs & Thermocouples | Measure & Source Accuracy: Cu10, NI-120, PT-100 (385/392/391-JIS), PT-200, PT-500, PT-1000 RTD Resolution: Cu10 = 0.01 °C TC Resolution: J: 0.15 °C, K: 0.45 °C, T: 0.35 °C, E: 0.35 °C, R: 0.95 °C, S: 0.55 °C, B: 1.4 °C, L: 0.45 °C, U: 0.6 °C, N: 0.4 °C General: J,K,T,E,L,N,U = 0.1 °C (0.1 °F); B,R,S = 1 °C (1 °F) | 
| Ramp Functions | Source functions: Voltage, current, resistance, frequency, temperature Ramps: Slow ramp, Fast ramp, 25% step-ramp | 
| Loop Power Function | 24 V, ±10%, max 22 mA (short-circuit protected) | 
| Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Steps: 25% and 100% of range | 
| Environmental | Operating Temp: -10 °C to +55 °C Storage Temp: -20 °C to 71 °C Operating Altitude: 3000 m | 
| Safety Approvals | EN 61010-1:1993, ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992 | 
| Mechanical & General | Size: 200 × 96 × 47 mm (7.9 × 3.8 × 1.9 in) Weight: 650 g (23 oz) Batteries: 4 × AA alkaline Battery Replacement: Separate compartment, accessible without breaking calibration seal Side Port: Pressure module connector / remote programming | 
Tech Specs
| Type | Hand Held | 
| Measure Voltage | Yes | 
| Loop Voltage Min | 0.01 mV (0.00001 V) | 
| Simulate Loop Voltage | Yes | 
| Loop Voltage Max | 30 V | 
| Voltage Measurement Max | 30 V | 
| Voltage Measurement Min | 0.01 mV (0.00001 V) | 
| Source/Simulate DC Current | Yes | 
| Measure DC Current | Yes | 
| Current Measurement Max | 24 mA | 
| Current Measurement Min | 0.001 mA | 
| Source/Simulate Resistance | Yes | 
| Measure Resistance | Yes | 
| Resistance Measurement Max | 4 KΩ | 
| Resistance Measurement Min | 5 Ω | 
| Source/Simulate Frequency | Yes | 
| Measure Frequency | Yes | 
| Frequency Measurement Max | 15 Hz | 
| Frequency Measurement Min | 1 Hz | 
| Measure RTD | Yes | 
| Measure Thermocouples | Yes | 
| Source/Simulate Pressure | No | 
| Pressure Modules Available | Yes | 
| Hart Compatible | No | 
| FieldBus Compatible | No | 
| Backlighted | Yes | 
| Graphical Screen | No | 
| Types RTD/Thermocouples Accepted | B, C, E, J, K, L, N, R, S, T, U | 
Test Equipment General Attributes
| Unique Features | Accuracies of 0.01%. Memory storage for up to 8 calibration results. Frequency totalizer and pulse train source mode. Two separate channels for simultaneous measure and source. | 
| Warranty | 3 Years | 
| Safety Approval | CSA | 
| Product Weight | 23 oz (1.44 lbs) | 
| Product Height | 1.9 in | 
| Product Length | 7.9 in | 
| Product Width | 3.8 in | 
| Data Logging | No | 
| HTS/Schedule B Number | 9030.39.0100 | 
| ECCN Number | 3A992 | 
| Calibration Included | NIST Calibration | 
| Power Supply Voltage | Battery Powered | 
| Country of Origin | Malaysia | 
Fluke 726 Multifunction Precision Process Calibrator
Key Features
- More precise measurement and calibration source performance, accuracies of 0.01%
- Two separate channels; measure, source and view process signals simultaneously
- Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
- Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
- Source mA with simultaneous pressure measurement to conduct valve and I/P tests
- Integrated pressure switch test captures set, reset and deadband of a switch
- Memory storage for up to 8 calibration results
- Transmitter error% calculation to interpret results without a calculator
- Perform fast linearity tests with auto step and auto ramp
- 24 V loop supply with simultaneous mA measurement
- Frequency totalizer and frequency pulse train source mode for flowmeter testing
- HART mode with 250 ohm resistor for HART instrumentation compatibility
- Custom RTD curves for certified RTD probes
- Improved reliability with new voltage input protection
- Three-year warranty
Fluke 726 Accessories
- Alligator Clips
- Banana Type Test Leads
- Calibration Pumps
- Cases
- Current Clamp Adaptors / Current Clamps
- DMM Probe Kits
- DMM Probes with Leads
- Hook Test Leads
- Pincer Test Leads
- Pressure Calibrator Modules
- Probe Bodies
- Telecom Test Leads
- Temperature Probes
Description
FLUKE 726 - Precision Multifunction Process Calibrator
The Fluke 726 is designed for the process industry with broad workload coverage, calibration power, and unsurpassed accuracy. It measures and sources almost all process parameters and can calibrate almost anything. It also interprets results without a calculator and stores measurement data for later analysis.
Features include a split-screen display, thermocouple input/output with automatic compensation, manual and automatic stepping/ramping, calibration screen storage, and remote control capability via PC.
Manufacturer Specifications
| Voltage DC | 30.000 V 0.01%+2 mV (upper) 20.000 V 0.01%+2 mV (lower) 90.00 mV 0.01%+10 µV -10.00 mV to 75.00 mV 0.025%+1 | 
| Current DC | 24.000 mA 0.01%+2 µA | 
| Resistance | 0–4000 Ω: ±0.015% | 
| Frequency | 2–1000 CPM: 0.05%+0.1 cpm 1–1000 Hz: 0.05%+0.1 Hz 1–15 kHz: 0.05%+0.01 kHz Sensitivity: 1 V p-p min | 
| Pressure | Accuracy 0.025% of range using 29 pressure modules (differential, gauge, vacuum, absolute, dual, high pressure) | 
| Source Accuracy (Voltage DC) | 100.00 mV 0.01%+10 µV 20.000 V 0.01%+2 mV -10.00 mV to 75.00 mV 0.025%+1 | 
| Source Accuracy (Current DC) | 24.000 mA (Source) 0.01%+2 µA 24.000 mA (Simulate) 0.01%+2 µA | 
| Source Accuracy (Resistance) | 5–400 Ω: 0.015%+0.1 Ω (0.1–0.5 mA) 5–400 Ω: 0.015%+0.05 Ω (0.5–3 mA) 400–1500 Ω: 0.015%+0.5 Ω (0.05–0.8 mA) 1500–4000 Ω: 0.015%+0.5 Ω (0.05–0.4 mA) | 
| Source Accuracy (Frequency) | 2–1000 CPM: 0.05% 1–1000 Hz: 0.05% 1–10 kHz: 0.25% 10–15 kHz: 0.5% Waveform: 5 V p-p squarewave | 
| RTDs & Thermocouples | Measure & Source Accuracy: Cu10, NI-120, PT-100 (385/392/391-JIS), PT-200, PT-500, PT-1000 RTD Resolution: Cu10 = 0.01 °C TC Resolution: J: 0.15 °C, K: 0.45 °C, T: 0.35 °C, E: 0.35 °C, R: 0.95 °C, S: 0.55 °C, B: 1.4 °C, L: 0.45 °C, U: 0.6 °C, N: 0.4 °C General: J,K,T,E,L,N,U = 0.1 °C (0.1 °F); B,R,S = 1 °C (1 °F) | 
| Ramp Functions | Source functions: Voltage, current, resistance, frequency, temperature Ramps: Slow ramp, Fast ramp, 25% step-ramp | 
| Loop Power Function | 24 V, ±10%, max 22 mA (short-circuit protected) | 
| Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Steps: 25% and 100% of range | 
| Environmental | Operating Temp: -10 °C to +55 °C Storage Temp: -20 °C to 71 °C Operating Altitude: 3000 m | 
| Safety Approvals | EN 61010-1:1993, ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992 | 
| Mechanical & General | Size: 200 × 96 × 47 mm (7.9 × 3.8 × 1.9 in) Weight: 650 g (23 oz) Batteries: 4 × AA alkaline Battery Replacement: Separate compartment, accessible without breaking calibration seal Side Port: Pressure module connector / remote programming | 
Tech Specs
| Type | Hand Held | 
| Measure Voltage | Yes | 
| Loop Voltage Min | 0.01 mV (0.00001 V) | 
| Simulate Loop Voltage | Yes | 
| Loop Voltage Max | 30 V | 
| Voltage Measurement Max | 30 V | 
| Voltage Measurement Min | 0.01 mV (0.00001 V) | 
| Source/Simulate DC Current | Yes | 
| Measure DC Current | Yes | 
| Current Measurement Max | 24 mA | 
| Current Measurement Min | 0.001 mA | 
| Source/Simulate Resistance | Yes | 
| Measure Resistance | Yes | 
| Resistance Measurement Max | 4 KΩ | 
| Resistance Measurement Min | 5 Ω | 
| Source/Simulate Frequency | Yes | 
| Measure Frequency | Yes | 
| Frequency Measurement Max | 15 Hz | 
| Frequency Measurement Min | 1 Hz | 
| Measure RTD | Yes | 
| Measure Thermocouples | Yes | 
| Source/Simulate Pressure | No | 
| Pressure Modules Available | Yes | 
| Hart Compatible | No | 
| FieldBus Compatible | No | 
| Backlighted | Yes | 
| Graphical Screen | No | 
| Types RTD/Thermocouples Accepted | B, C, E, J, K, L, N, R, S, T, U | 
Test Equipment General Attributes
| Unique Features | Accuracies of 0.01%. Memory storage for up to 8 calibration results. Frequency totalizer and pulse train source mode. Two separate channels for simultaneous measure and source. | 
| Warranty | 3 Years | 
| Safety Approval | CSA | 
| Product Weight | 23 oz (1.44 lbs) | 
| Product Height | 1.9 in | 
| Product Length | 7.9 in | 
| Product Width | 3.8 in | 
| Data Logging | No | 
| HTS/Schedule B Number | 9030.39.0100 | 
| ECCN Number | 3A992 | 
| Calibration Included | NIST Calibration | 
| Power Supply Voltage | Battery Powered | 
| Country of Origin | Malaysia | 
Fluke 726 Multifunction Precision Process Calibrator
- Regular price
- $0.00
- Sale price
- $0.00
- Regular price
- 
				
Couldn't load pickup availability
Popup Title
Popup Title
 
 
					Check Out These Related Products
We provide a diverse choice of reliable safety solutions from top manufacturers such as 3M, Avon Protection, BW Technologies, MSA Safety, and Philips, which are recognized for their performance and dependability. Every product, from protective clothing to sophisticated detection systems, Guardian Safety Supply provides original, high-quality equipment that satisfies your safety requirements.